BFSL
This state-of-the-art blade fuse was realized by reducing the width of the BFMN to offer space reduction
General Specification
- Rated Voltage
- DC32V
- Breaking Capacity
- 1000A
- Operation Temperature
- -40℃ - 120℃
- Insertion Force
- -
- Extraction Force
- -
- Standard Packaging
- 18,000
- Standard
- ISO8820-12
Please contact us for the details of operating temperature.
Time-Current Characteristic:All ratings
| % of Ampere Rating(A) | Operating Time | |
| MIN | MAX | |
| 110% | 100 hrs. | - |
| 135% | 0.75 sec. | 120 sec. |
| 160% | 0.25 sec. | 50 sec. |
| 200% | 0.15 sec. | 5 sec. |
| 350% | 0.04 sec. | 0.5 sec. |
| 600% | 0.02 sec. | 0.1 sec. |
The fuse characteristic may change depending on the conditions of use.
Product Lineup
| Ampere Rating(A) | Part Number | Housing Colors | Resistance Value | Voltage Drop |
| 3A | 1168 | Violet | Coming up | Coming up |
| 4A | 1169 | Pink | Coming up | Coming up |
| 5A | 1173 | Tan | 17.3 mΩ | 117 mV |
| 7.5A | 1174 | Brown | 10.7 mΩ | 109 mV |
| 10A | 1175 | Red | 7.85 mΩ | 104 mV |
| 15A | 1176 | Blue | 5.05 mΩ | 100 mV |
| 20A | 1177 | Yellow | 3.65 mΩ | 95 mV |
| 25A | 1178 | White(natural) | 2.75 mΩ | 88 mV |
| 30A | 1179 | Green | 2.18 mΩ | 82 mV |
Voltage drop: apply 100% of the rated current.
Adjusting the specification for 3A and 4A. Please contact us for the details.