SBFW-L (M5)

International standard products RoHS ELV

General Specification

Rated Voltage
DC58V
Breaking Capacity
1000A
Recommended Torque
4.5±1
Operation Temperature
-40℃ - 120℃
Insertion Force
-
Extraction Force
-
Standard Packaging
2,000
Standard
ISO8820-5

1 Please contact us for the details of operating temperature.
2 Except for the breaking capacity

Time-Current Characteristic:All ratings

% of Ampere Rating(A) Operating Time
MIN MAX
100% 100 hrs. -
110% 4 hrs. -
150% 90 sec. 3600 sec.
200% 3 sec. 100 sec.
300% 0.3 sec. 3 sec.
500% 0.1 sec. 1 sec.

The fuse characteristic may change depending on the conditions of use.

Product Lineup

Ampere Rating(A) Part Number Housing Colors Resistance Value Voltage Drop
30A 3139 Orange 2.11 mΩ 86 mV
40A 3149 Green 1.4 mΩ 77 mV
50A 3159 Red 1.18 mΩ 73 mV
60A 3169 Yellow 0.89 mΩ 71 mV
70A 3179 Brown 0.72 mΩ 66 mV
80A 3189 White 0.47 mΩ 51 mV
100A 3107 Blue 0.41 mΩ 58 mV
125A 3117 Pink 0.35 mΩ 59 mV

Voltage drop: apply 100% of the rated current.

Data sheet

Drawing:2D(PDF)
Time-Current Characteristic
Certificate of Non-use : RoHs
Certificate of Non-use : ELV

Automotive Fuses