BFSL-3
General Specification
- Rated Voltage
- DC32V
- Breaking Capacity
- 1000A
- Operation Temperature
- -40℃ - 120℃
- Insertion Force
- -
- Extraction Force
- -
- Standard Packaging
- 10,000
- Standard
- ISO8820-13
Please contact us for the details of operating temperature.
Time-Current Characteristic:All ratings
% of Ampere Rating(A) | Operating Time | |
MIN | MAX | |
110% | 100 hrs. | - |
135% | 0.75 sec. | 120 sec. |
160% | 0.25 sec. | 50 sec. |
200% | 0.15 sec. | 5 sec. |
350% | 0.04 sec. | 0.5 sec. |
600% | 0.02 sec. | 0.1 sec. |
The fuse characteristic may change depending on the conditions of use.
Product Lineup
Ampere Rating(A) | Part Number | Housing Colors | Resistance Value | Voltage Drop |
5A | 1183 | Tan | 16.9 mΩ | 110 mV |
7.5A | 1184 | Brown | 10.6 mΩ | 104 mV |
10A | 1185 | Red | 7.94 mΩ | 104 mV |
15A | 1186 | Blue | 5.07 mΩ | 97 mV |
Voltage drop: apply 100% of the rated current.