General Specification

Rated Voltage
DC32V
Breaking Capacity
1000A
Operation Temperature
-40℃ - 100℃
Standard Packaging
300
Standard
-

Please contact us for the details of operating temperature.

Time-Current Characteristic:All ratings

% of Ampere Rating(A) Operating Time
MIN MAX
110% 4 hrs. -
200% 5 sec. 100 sec.
350% 0.2 sec. 7 sec.
600% 0.04 sec. 1 sec.

The fuse characteristic may change depending on the conditions of use.

Product Lineup

Part Number FUSE 1 FUSE 2
3580 100A 70A
3581 120A 70A
3582 100A 40A
3583 120A 40A
3584 100A 60A
3585 80A 50A
3589 80A 70A
3579 100A 30A
3621 60A 50A
3622 120A 60A

Data sheet

Drawing:2D(PDF)