SBFW-K

International standard products RoHS ELV
High-amperage bolt type fuse
SBFW-K 商品写真

General Specification

Rated Voltage
DC32V
Breaking Capacity
2000A
Recommended Torque
12.0±1
Operation Temperature
-40℃ - 120℃
Insertion Force
-
Extraction Force
-
Standard Packaging
1,200
Standard
ISO8820-5

Please contact us for the details of operating temperature.

Time-Current Characteristic:All ratings

Time-Current Characteristic:All ratings【 80A~250A】

% of Ampere Rating(A) Operating Time
MIN MAX
100% 4 hrs. -
135% 120 sec. 1800 sec.
200% 1 sec. 15 sec.
350% 0.3 sec. 5 sec.
600% 0.1 sec. 1 sec.

Time-Current Characteristic:All ratings【 300A~500A】

% of Ampere Rating(A) Operating Time
MIN MAX
75% 4 hrs. -
200% 1 sec. 15 sec.
350% 0.5 sec. 5 sec.
600% 0.1 sec. 1 sec.

The fuse characteristic may change depending on the conditions of use.

Product Lineup

Ampere Rating(A) Part Number Housing Colors Resistance Value Voltage Drop
80A 3102 Red 0.72 mΩ 85 mV
100A 3112 Yellow 0.58 mΩ 83 mV
125A 3122 Green 0.44 mΩ 82 mV
150A 3132 Orange 0.36 mΩ 89 mV
175A 3142 White 0.32 mΩ 91 mV
200A 3152 Blue 0.3 mΩ 95 mV
225A 3162 Light brown 0.26 mΩ 97 mV
250A 3172 Pink 0.24 mΩ 100 mV
300A 3182 Gray 0.2 mΩ 63 mV
350A 3134 Dark Green 0.18 mΩ 50 mV
400A 3144 Violet 0.16 mΩ 52 mV
450A 3154 Dark yellow 0.14 mΩ 56 mV
500A 3164 Brown 0.13 mΩ 63 mV

Voltage drop: apply 100% of the rated current(300A-500A:at 75% of the rated current).

Data sheet

Drawing:2D(PDF)
Time-Current Characteristic
Certificate of Non-use : RoHs
Certificate of Non-use : ELV

Automotive Fuses