MUSB-M2
General Specification
- Rated Voltage
- DC32V
- Breaking Capacity
- 1000A
- Operation Temperature
- -40℃ - 100℃
- Standard Packaging
- 160
- Standard
- -
Please contact us for the details of operating temperature.
Time-Current Characteristic:All ratings
% of Ampere Rating(A) | Operating Time | |
MIN | MAX | |
110% | 4 hrs. | - |
135% | 60(-) sec. | 1800(-) sec. |
200% | 5 sec. | 100 sec. |
350% | 0.2 sec. | 7 sec. |
600% | 0.04 sec. | 1 sec. |
The fuse characteristic may change depending on the conditions of use.
Product Lineup
Part Number | FUSE 1 | FUSE 2 | FUSE 3 | FUSE 4 | FUSE 5 | FUSE 6 | FUSE 7 | FUSE 8 |
3624 | 80A | 50A | 50A | 50A | 30A | 30A | 30A | 120A |
3625 | 80A | 50A | 50A | 50A | 30A | 30A | 30A | 140A |
3731 | 80A | 50A | 50A | 40A | 40A | 30A | 30A | 140A |
3732 | 80A | 50A | 50A | 40A | 40A | 30A | 30A | 150A |
3733 | 50A | 50A | 50A | 40A | 30A | 30A | 40A | 100A |
3734 | 80A | 50A | 50A | 30A | 30A | 30A | 40A | 140A |
3735 | 80A | 50A | 50A | 50A | 40A | 30A | 30A | 150A |