General Specification

Rated Voltage
DC32V
Breaking Capacity
1000A
Recommended Torque
-
Operation Temperature
-40℃ - 120℃
Insertion Force
44.1N and less
Extraction Force
4N - 24.5N
Standard Packaging
4000
Standard
-

Please contact us for the details of operating temperature.

Time-Current Characteristic:All ratings

% of Ampere Rating(A) Operating Time
MIN MAX
110% 100 hrs. -
135% 60 sec. 1800 sec.
200% 2 sec. 60 sec.
350% 0.2 sec. 7 sec.
600% 0.04 sec. 1 sec.

The fuse characteristic may change depending on the conditions of use.

Product Lineup

Ampere Rating(A) Part Number Housing Colors Resistance Value Voltage Drop
15A 3125 Gray Coming up Coming up
20A 3145 Light blue Coming up 93.2 mV
25A 3155 White Coming up 92.6 mV
30A 3165 Pink Coming up 79.6 mV
40A 3175 Green Coming up 75.8 mV
50A 3185 Red Coming up 83.7 mV
60A 3195 Yellow Coming up 70.5 mV

1 Voltage drop: apply 100% of the rated current.
2 *For the details of 15A, please contact us.

Data sheet

Time-Current Characteristic
Certificate of Non-use : RoHs
Certificate of Non-use : ELV

Automotive Fuses