| % of Ampere Rating (A) | Operating Time | |
| Min | Max | |
| 110% | 100 hrs. | - |
| 135% | 60 sec. | 1800 sec. |
| 200% | 5 sec. | 60 sec. |
| 350% | 0.2 sec. | 7 sec. |
| 600% | 0.04 sec. | 1 sec. |
Rated Voltage: DC32V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 10,000 cycles. Each cycle
consists of an nerrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
| Part Number | Ampere Rating (A) | Housing Color |
| 3123 | 20 | Light Blue |
| 3173 | 25 | White |
| 3133 | 30 | Pink |
| 3143 | 40 | Green |