| % of Ampere Rating (A) | Operating Time | |
| Min | Max | |
| 100% | 100 hrs. | - |
| 110% | 4 hrs. | - |
| 150% | 90 sec. | 3600 sec. |
| 200% | 3 sec. | 100 sec. |
| 300% | 0.3 sec. | 3 sec. |
| 500% | 0.1 sec. | 1 sec. |
Rated Voltage: DC58V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 10,000 cycles. Each cycle
consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
Standard:ISO 8820/JASO D612
| Part Number | Ampere Rating (A) | Housing Color |
| 3130 | 30 | Orange |
| 3140 | 40 | Green |
| 3150 | 50 | Red |
| 3160 | 60 | Yellow |
| 3170 | 70 | Brown |
| 3180 | 80 | White |
| 3100 | 100 | Blue |
| 3110 | 125 | Pink |
| 3120 | 150 | Gray |
![]()
| % of Ampere Rating (A) | Operating Time | |
| Min | Max | |
| 110% | 100 hrs. | - |
| 200% | 5 sec. | 100 sec. |
| 350% | 0.2 sec. | 7 sec. |
| 600% | 0.04 sec. | 1 sec. |
Rated Voltage: DC32V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 10,000 cycles. Each cycle consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
Standard:ISO 8820/JASO D612
| Part Number | Ampere Rating (A) | Housing Color |
| 3233 | 30 | Pink |
| 3243 | 40 | Green |
| 3253 | 50 | Red |
| 3263 | 60 | Yellow |
| 3273 | 70 | Brown |
| 3283 | 80 | Black |
| 3303 | 100 | Blue |
| 3323 | 120 | White |
| 3343 | 140 | Maroon |