| % of Ampere Rating (A) | Operating Time | |
| Min | Max | |
| 110% | 100 hrs. | - |
| 200% | 5 sec. | 100 sec. |
| 350% | 0.2 sec. | 7 sec. |
| 600% | 0.04 sec. | 1 sec. |
Rated Voltage: DC58V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 10,000 cycles. Each cycle consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.075%/1°C
Standard:ISO 8820/JASO D612
| Part Number | Ampere Rating (A) | Housing Color |
| 3027 | 20 | Light Blue |
| 3037 | 30 | Pink |
| 3047 | 40 | Green |
| 3057 | 50 | Red |
| 3067 | 60 | Yellow |
![]()
| % of Ampere Rating (A) | Operating Time | |
| Min | Max | |
| 110% | 100 hrs. | - |
| 200% | 5 sec. | 100 sec. |
| 350% | 0.2 sec. | 7 sec. |
| 600% | 0.04 sec. | 1 sec. |
Rated Voltage: DC58V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 10,000 cycles. Each cycle consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
Standard:ISO 8820/JASO D612
| Part Number | Ampere Rating (A) | Housing Color |
| 3136 | 30 | Pink |
| 3146 | 40 | Green |
| 3156 | 50 | Red |
| 3166 | 60 | Yellow |
| 3176 | 70 | Brown |
| 3186 | 80 | Black |
| 3206 | 100 | Blue |
| 3226 | 120 | White |
| 3246 | 140 | Maroon |