| % of Ampere Rating (A) | Operating Time | |||
| 5A-20A | 25A or above | |||
| Min | Max | Min | Max | |
| 110% | 2 hrs. or more | - | 2 hrs or more | - |
| 135% | - | 180 sec. | - | 300 sec. |
| 150% | - | 15 sec. | - | 30 sec. |
Rated Voltage: DC32V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 70% of the rated current is applied for 250,000 cycles. Each cycle consists of an interrupted current with the pattern of 10 seconds ON and 10 seconds OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.15%/1°C
Standard:ISO 8820/SAE J1284/JASO D612
| Length | Part Number | Ampere Rating (A) | Element Color |
| 25mm | 2105 | 5 | Brown |
| 2107 | 7 | Black | |
| 2110 | 10 | Yellow | |
| 2115 | 15 | Blue | |
| 2120 | 20 | Green | |
| 2125 | 25 | Violet | |
| 2130 | 30 | Natural | |
| 30mm | 2005 | 5 | Brown |
| 2008 | 8 | Natural | |
| 2010 | 10 | Yellow | |
| 2015 | 15 | Blue | |
| 2020 | 20 | Green | |
| 2025 | 25 | Violet | |
| 2030 | 30 | Natural | |
| 2035 | 35 | Natural | |
| 2040 | 40 | Natural | |
| 2050 | 50 | Natural |